Systems and Devices on a Project

Systems and Devices on a Project

What a system is, adding one, its devices and batteries, and the one history per system.

4 min read
Updated Sep 22, 2026
Systems & Logbook

Systems and Devices on a Project

A system is a piece of life-safety or building equipment you look after at a client's site — a fire alarm, the emergency lighting, an intruder alarm, a distribution board. It lives on the project, carries its devices, batteries, certificates and logbook, and is what the routine test programme and the service schedule hang off.

Tip

Open a project and choose Systems under the Site group in the page's sidebar. The Logbook is under Records. Systems & Devices is listed under Company Settings → Features and is on by default; it needs Projects on as well.

Adding a System

Click Add (or the + in the systems list) and fill in the Add System form:

Field Notes
System Name, System Type Required. The type brings its compliance standard and its routine test rules
Compliance Standard Filled from the type when left blank — BS 5839-1 for a fire alarm, BS 5266-1 for emergency lights, BS 7671 for electrical installations
Location, User Code, Engineer Code, Key Location Where it is and how to get into it. Both codes are stored encrypted, and they are the only place a panel's user and engineer codes are kept — no system type asks for them a second time
Contract Type Maintenance Contract, Monitoring Only, Maintenance & Monitoring, or Ad-hoc / Call Out — decides whether service jobs are generated automatically
Installation Date, Service Interval (months), Last Service Date, Next Service Date The service schedule. Missed tests are never counted from before the installation date
Has battery backup, Has disk backup / storage Switch on the Battery Backup and Storage cards

Every company starts with twelve system types — Fire Alarm, Intruder Alarm, CCTV, Access Control, Distribution Board, Automation Panel, Emergency Lights, Intercom, Nurse Call, Warden Call, Electrical Installation, Networking — and can add its own under Projects → Settings → System Types.

The System Page

With a system selected, the middle column shows its cards:

  • Devices — call points, sounders, detectors, luminaires, cameras… each with a name, type, manufacturer, serial, IP address, location, zone and Loop/Address, a status (Active, Inactive, Faulty, Replaced, Removed) and its own last tested date. History opens one timeline for the whole system: log entries, jobs, batteries and battery checks, certificates and activity, newest first
  • Tests — the routine test programme for this system; see Routine Test Schedules
  • Battery Backup — see below
  • Storage, System Configuration, Certificates

The right column holds System Info and the Panel details.

System Configuration

The System Configuration card holds the details an engineer needs to get into the equipment — the panel login, its activation code, the recovery email, the network settings — and asks for whatever that type of system needs, so it looks different on a CCTV system than on a fire alarm. See System Configuration.

Batteries

Switch Battery Backup on and record each battery with its Voltage (V), Amps (Ah) and Date Installed. A battery is expected to last four years from installation unless a different expiry is recorded; it shows Expiring for the last 60 days and Expired after that. Replace marks the old one as replaced (it moves into Battery History) and records a new one from today.

Engineers check batteries on a job — Pass, Fail or N/A, with the measured voltage — and can replace one from there; the old battery is marked replaced against that job. A failed battery joins the job's failed items, ready for a remedial job. Batteries past or near their replacement date appear on your dashboard's action queue as Schedule replacement.

Deleting

Delete on a system removes it with all its devices and certificates. Prefer marking a system inactive (untick System is active) if the equipment was decommissioned but the history matters.